Últimas versiones - A4400 VA4 Pro / Virtual Unit
Versión 2.83
03.05.2023
- Preview of values in a route tree (see manual Route / Route Tree)
- Difference form last and reference values in route (see manual Route / Last and reference values)
- Angles Counting marks (with or against rotation) (see manual MENU / SETTINGS / Global Settings / Angles Counting)
- Oversampling (higher sampling frequency defined by user) (see manual Analyzer / Edit Measurement / Sampling Freq)
- New frequency ranges in octave spectrum (see manual Octave Analysis / Measurement Settings / Frequency Range
- Finishing Averaging (see manual Analyzer / Edit Measurement / Avg)
- Time axe unit in degrees (see manual Analyzer / Graph Properties / Time Axe Unit)
- External trigger edge and level removed from trigger menu and united with tacho sensor (see manual MENU / SETTINGS / Tacho / External)
- Sensors list import (see manual MENU / SETTINGS / AC Sensors / Sensors list import)
- Delta cursor value initialized according to the speed (see manual Analyzer / Graph Properties / Cursor)
- Retrig in route (see manual Route / Route Meas Mode)
- Export a record to csv (see manual Recorder / Project Menu / Export to csv)
- Report for advanced balancer (see manual Advanced Balancer / Balancer Menu / Balancing Report)
Versión 2.81
03.03.2023
- Angles (phases) with or against rotation (see VA5Pro manual MENU / SETTINGS / Global Settings / Angles Counting)
- Balancing: new design and terminology (see VA5Pro manual Balancer)
- Balancing: operating speed parameter (see VA5Pro manual Balancer / Rotor Settings / Operating Speed)
- Balancing: trial weight position (see VA5Pro manual Balancer / Single Plane Balancing / Trial Run)
- Balancing: more than 255 values in averaging available
- Advanced Balancing: trial weight position (see VA5Pro manual Advanced Balancer / Balancing Procedure / Trial Runs)
- Sensor's name added to csv export (see VA5Pro manual Analyzer / Meas Menu / Export to csv)
- Canceled restrictions of highest sampling frequency (see VA5Pro manual Analyzer / Edit Measurement / Band fmax)
Versión 2.80
09.06.2022
- Frf format (see manual Analyzer / Graph Properties / Frf Format)
- Flat top window (see manual Analyzer / Edit Measurement / Window)
- The lin / log / dB choice for overall value (see manual Analyzer / Graph Properties / Axe y)
- MCSA: thd shown in table (see manual MCSA / MCSA Screen / Frequency table and thd)
- Continual saving in Route (see DDS manual)
Versión 2.79
16.02.2022
- New runup trigger mode - asap all (see manual Global properties / Trigger Settings)
- The user entered frequency in amp+phase measurement (see manual The Analyzer mode / amp+phase measurement)
- Editable basic meas list (see manual The Analyzer mode / New Meas Creation / New Basic)
- Notes in csv header (see manual The Analyzer mode / CSV file description)
- Polar graph in balancer (see manual The Balancer / Single Plane Balancing / Run 1)</li>
Versión 2.78
26.07.2021
- 16 bit wav encoding (see manual Global Properties / Global Settings / Wav Encoding)
- Limits multipliers (enables to increase or decrease limits) and Acc fmin in FASIT (see manual The FASIT / Setup)
- Adash limits enabled for velocity measurement with fmin lower than 10 Hz (see manual The Analyzer mode / Next meas functions / Limits / Adash Limits)
- Adash limits enabled for acceleration measurement with fmin higher than 500 Hz (see manual The Analyzer mode / Next meas functions / Limits / Adash Limits)
Versión 2.76
19.05.2021
- Limit values for static measurements (see manual Analyzer / Meas Menu / Limits)
- New measurement type - complex Smax (see manual Analyzer / Complex Smax)
- Minimum and Maximum values during averaging (see manual Analyzer / Edit Measurement / Avg)
- ADS: changing channel without losing readings (see manual ADS / ADS Settings / Measurement Definition)
Versión 2.75
02.02.2021
- Runup minimum and maximum speed (see manual Global properties / Trigger Settings)
- Negative Averaging (see manual Global properties / Trigger Settings / Negative Averaging)
- Negative Averaging in Bump Test (see manual Bump Test / Settings / Negative Averaging)
- Balancer: circumferential distance of balancing mass (see manual Balancer / Single plane balancing / RUN2 - the RESULT Screen)
- Route status symbols like VA3 (✓, !, .) (see manual Route / Route Status)
- Marking of non-exported routes (see manual The Route / Route measurement)
- Battery percent in About dialog (see manual Global properties / The About...)
- Export bump test to analyzer (see manual Bump Test / Analyse)
Versión 2.74
23.11.2020
- Limits in the route (see manual The Route / Limits)
- Balancer: Unbalance value displayed (see manual The Balancer / Single Plane Balancing
- Balancer: The "Remove trial" item in basic settings menu (see manual The Balancer / Basic Settings)
- ADS: Vibration scale in animation (see manual ADS / ADS Settings / Vibration Scale)
- ADS: Zoom and move using touch screen (see manual ADS / Buttons for Machine View / Zoom/Move/Rotation
Versión 2.72
25.05.2020
- Adjustable order in amp+phase measurement (see manual The Analyzer mode / amp+phase measurement)
- Adjustable order in phase shift measurement (see manual The Analyzer mode / Phase shift measurement)
- Adjustable resolution in orders measurement (see manual The Analyzer mode / orders measurement)
Versión 2.71
28.04.2020
- Physical unit and frequency range in bump test (see manual Bump Test / Settings)
- Graph unit for spectra (see manual The Analyzer Mode / The Analyzer buffons description / Graph Properties / Graph Unit)
- Screenshots in lossless png format instead of jpg (see manual Global Properties / Screenshot)
- Bearing fault frequencies: BSF2 instead of BSF (see manual The Analyzer Mode / The Analyzer buttons description / Graph Properties / Bearing Faults)
Versión 2.70
16.12.2019
- Adjustable FASIT limits (see manual FASIT / Setup)
- Sensor's name (see manual Sensors Properties / AC Sensors)
- Spectrum value type (RMS, 0-P, P-P) defined globally (see manual Global Properties / Spectrum Settings)
Versión 2.69
03.06.2019
- Export of all unexported projects at once (see manual Global Properties / Export All)
- Time signal with DC offset (gap) (see manual The Analyzer mode/Time signal measurement/Time signal with DC offset (gap)
- Using external USB drive for exports (see manual General information/Connection to the computer/VAx_DISC)
Versión 2.67
07.08.2018
- New highest resolution (speed / 1024) is available for balancing and 1x ampl + phase measurement (see manual The Analyzer mode/New Meas creation/New Advanced/Resolution for details)
- New function "Auto-forward" jump to next point in route (instead of "start next" function), (see manual Global properties/Global Settings/Route Auto Forward for details)
- New "Waiting for retrig" window with more user information (see manual Global properties/Trigger Settings/RunUp Mode)
- New "Waiting for trigger" window with more user information (see manual Global properties/Trigger Settings/Trigger Source)
- Lower "Band fmin" than 10Hz is available for FASIT (see manual The FASIT/Set-up/Band fmin)
- New Zoom and Cursor controll by mouse in A4410 Virtual Unit (see manual A4400 VA4 Pro vs. A4404 SAB/A4404 SAB/Graph control by mouse)
Versión 2.66
27.03.2018
- More than 255 averages enabled
- ACMT detect type RMS or PEAK (see manual The Analyzer mode/ACMT measurement)
Versión 2.64
24.01.2018
- Possibility to play different channels in left and right headphone (see manual The Stethoscope / Playback Settings)
- Full spectrum (see manual The Analyzer mode / Full spectrum)
- Order full spectrum (see manual The Analyzer mode / Order full Spectrum)
Versión 2.59
06.07.2017
- Export of records from data cell to Recorder (see manual The Analyzer Mode/Next Meas functions/Export to Records)
- Export of records from data cell to VA4_DISC (see manual The Analyzer Mode/Next Meas functions/Export to VA4_DISC)
- "Remove trial mass" question after trial run (see manual The Balancer/Single plane balancing/RUN 2 - the TRIAL MASS screen)
- Different number of blades fot each plane (see manual The Balancer/Balancer Settings/Basic Settings)
- Balancing mass splitting (see manual The Balancer/Single plane balancing/RUN 2 - the RESULT screen)
- Change of blades (see manual The Balancer/Single plane balancing/RUN 2 - the RESULT screen)
- Various correction mass radius for each plane (see manual The Balancer/Balancer Settings/Rotor Settings)
- Temporary records deleting (see manual The Recorder/Temporary records)
Versión 2.58
16.05.2017
- Time synchro averaging for spectra (see manual The Analyzer Mode/New Meas creation/New Advanced/Averaging)
- Ampl Tacho (see manual Global Properties/Trigger Settings/Use Ampl Tacho)
- You can turn on/off orders in filtered orbit (see manual Analyzer/Filtered Orbit Measurement)
Versión 2.57
23.03.2017
- Order spectrum (Analyzer/Order spectrum)
- FFT output normalization - power spectrum, power spectral density, ... (Analyzer/Graph Properties/FFT Output)
- PAS (=Phase Assigned Spectrum) as FRF result (Analyzer/New Mead Creation/New Advanced)
- "Manual Entry" parameter in DC measurement (Analyzer/DC measurement)
- A4410 installer
Versión 2.56
06.01.2017
- Filtered orbit measurement (Analyzer/Filtered Orbit Measurement)
- Ultrasound measurement (Analyzer/Ultrasound)
- Circular view for time waveform (Analyzer/Graph Properties/View (time waveform)
Versión 2.55
06.12.2016
- Export to wav Settings (Recorder/Editing of Record)
- Min speed (Sensors properies/Tacho)
Versión 2.54
04.11.2016
- Minor fixes
Versión 2.53
26.10.2016
- Ultrasound Module
- Route sensors checking (menu Global/Global Settings/Check Route Sensors)
- Cursor on spectrograph
- Tacho marks in orbit graph
Versión 2.52
22.09.2016
- New notes format
- Settling Prolongation (Sensors/Settling Prolongation)
- Balancer: negative value of trial mass enabled (removing mass)
- Bumptest: integration in spectrum
- Route creation in instrument
Versión 2.51
20.06.2016
- Averaging types for static values (linear, maximum, minimum, median)
- Reference spectrum drawed bellow signal
Versión 2.50
03.06.2016
- Faster saving data in route
Versión 2.49
26.04.2016
- New appearance of FASIT
- FASIT as meas type
Versión 2.48
05.04.2016
- Variable Speed Detection
- True and Scaled detect types
Versión 2.47
11.02.2016
- Appearance dialog (Global/Appearance)
Versión 2.46
29.09.2015
- New skin
Versión 2.45
25.08.2015
- Manualy entered speed valid for whole route
Versión 2.44
20.08.2015
- Minor fixes
Versión 2.43
14.08.2015
- Initialization delay shortened
Versión 2.42
26.05.2015
- Minor fixes
Versión 2.39
16.05.2015
- New module: ADS
Versión 2.41
14.05.2015
- Global/Global Settings/Record Analysis Start
- Imperial unit in basic meas
Versión 2.40
11.05.2015
- Minor fixes
Versión 2.38
11.03.2015
- Minor fixes
Versión 2.37
21.01.2015
- Minor fixes
Versión 2.36
13.01.2015
- New data type: record
- Export of all meases in a set to csv
Versión 2.35
12.12.2014
- Number of used ac channels in point list
- Channel number in meas list
Versión 2.34
21.10.2014
- Export of runup trends
Versión 2.33
19.09.2014
- Up to 8388608 samples is time waveform
- Up to 3276800 lines in spektrum
Versión 2.32
18.09.2014
- New coherence vizualization in fresp graph
- New runup mode - time or revolution
- Export to uff - all meases in history
Versión 2.29
11.07.2014
- Virtual unit: up to 4 SABs possible to connect to one PC
Versión 2.27
24.04.2014
- Selectable runup trend time axe - real time, relative (Global/Runup/Trend Time Axe)
- Parameter "Trend Length" from "Global/Global Settings" removed to "Global/Runup"
- Integration enabled in octave spectrum
- Selectable y-axe in octave spectrum (linear, logaritmic, decibel)
- Total mass in balancer (Balancer/Total Mass)
- Parameter fmin is possible to set to any value greater than one even if integration used
- Ord cursor in spec graph (frequency / speed frequency)
- Voltage units allowed for g-demod
- New image in balancer: overhung rotor for 2 planes
- Serial number in virtual unit's licence file name
- Export of trend data into csv file
- Headers in csv files
Versión 2.25
03.03.2014
- New detect type of wideband: AVG
- Help in instrument (Global/Help)
Versión 2.24
29.01.2014
- Runup trend divided into parts with selectable length (Global/Runup)
Versión 2.22
11.10.2013
- "Enter Speed" item for set: you can enter the speed before measurement
- Tacho sensor: pulses per rotation as floating point number
- "Stop if ICP Error" in global settings
- "Route START Button" in global settings: "start next" enables immediate start of measuring on next point
- "Graph Lines" in spectrum graph properties (Graph Properties): drawing spectrum methods (continuous / discrete)
- Fresp: amplitudes view ("Graph Properties/Fresp View")
- Clock on screen
- New date format - mm/dd/yyyy + time displayed with a.m./p.m.
- Project list: time of last modification displayed on status bar
- Runup trend: x-axe notes in format hh:mm:ss
- Amplitudes ratio in phase shift
- Polar graph in phase shift
- Screenshots (Global/Screenshot)
Versión 2.21
09.09.2013
- Trends during measurement
- New data type: phase shift
- New type of trigger: manual sequential (same as manual but waits between averages)
- Phase in spectrum
- Dynamic factor in Balancer
- Recorder cursor in absolute time
- Envelope changed to Demod
Versión 2.20
07.06.2013
- Button "Save" for settings dialogs
- Integration in orbit
- Envelope measurements: ENV fmin minimal value decreased to 5Hz (instead of 100Hz)
Versión 2.19
27.05.2013
- New module: Bump Test
- Spectrum: time signal view, editing of parameters of spec windows ("Graph Properties/Spec View")
- RMS and 0P values in time signal graph
- Total value in spec graph
- Stethoscope: setupable playback speed
- Speed period view in time signal, orbit, ACMT and cepstrum (Graph Properties/Speed Period...)
- Bearing faults view in time signal, ACMT and cepstrum (Graph Properties/FTF Period...)
- Synch Table in spectrum (Graph Properties/Synch Table)
Versión 2.18
25.03.2013
- Zoom spectrum
Versión 2.17
15.01.2013
- Periodic cursor in ACMT
- Setupable edge for external trigger ("Global/Trigger Settings/External Trig Edge")
- Clear Last Data in set (point)
Versión 2.16
03.12.2012
- Longer time waveform (up to 1M samples)
- Free memory indicator during record acquisition
Versión 2.15
23.11.2012
- New data type: cepstrum
- New detect types of wideband: Crest and Kurtosis
- Sound playback during the record analysis
- Data export to uff ("Meas/Save to uff")
- Data export to wav ("Meas/Save to wav")
- Data export to csv ("Meas/Save to csv")
- Saving instrument settings as profile ("Global/Profiles")
- Tacho sensor settings replaced from "Global/Trigger Settings" to "Sensors/Tacho"
- Route: "Measurement is not completed" notification
- Bearing and ISO 10816 settings for each channel ("Sensors/AC1 - AC4")
- Menu "Sensors/All Bearings": same bearing for all channels
- Menu "Sensors/All ISO": same ISO for all channels
- Export analyzer project to runup ("Project/Export to runup")
- Export runup project to analyzer ("Project/Export to analyzer")
- Button "Find": finds item in list
- User defineable graphs colors ("Global/Global Settings/Background Color - Create")
- Balancer: remove balancing masses ("Balancer/Basic Settings/Balancing Masses")
Versión 2.14
18.06.2012
- Evaluation of ISO 10816 divided to A, B, C, D
- Continuous record preview
- Remote desktop control
- New data type: octave analysis
- New data type: sound level
- New data type: equivalent sound level
- New module: octave analysis
- Trigger settings: new item Pulses per rotation
Versión 2.13
26.03.2012
- Enter value of cursor position by number possible ("Graph Properties/Cursor Position")
- Orda and aps view in RMS, 0P, PP ("Graph Properties/Detect Type")
- ICP channels powered permanently, shorter measurement initialization
- Balancer: balancing vector in balancing protocol
- Peak hold averaging
- Record preview during analysis
- FASIT: ISO 10816
- Graph wideband: ISO 10816 settings and limits displayed if used
- Envelope measurements: ENV fmax minimal value decreased to 200Hz (instead of 1600Hz)
- Statistics of static trends ("Graph Properties/Statistics Table")
Versión 2.12
06.02.2012
- Speed control replaced by Trigger control
- Balancer: new settings dialogs
- Balancer: recomended trial calculation
- FASIT: new settings dialog
- Lubri: new settings dialog
- FASIT: harmonics displayed as triangles bellow axe
Versión 2.11
05.01.2012
- Virtual unit
Versión 2.09
28.11.2011
- Centerline values A,B,X,Y displayed together
- DC gap channel in ac channel settings + orbit with gaps ("Sensors/DC gap channel")
Versión 2.08
09.11.2011
- Spec cascade: first in front or last in front view ("Graph Properties/Order Z")
- New mode: Lubri
- Selectable record analysis speed: fast or real time ("Global Settings/Record analysis speed")
Versión 2.07
30.09.2011
- New mode: FASIT
- Balancer: advisor removed
- Balancer: keep trial in two planes possible
Versión 2.06
10.08.2011
- Time cursor in orbit
- VA4_DISC check during startup
- Export of records to WAV ("Project/Export to WAV")
- Selectable range of phase -180°,180° or 0°,360° ("Global Settings/Phase range")
- Bearing database + bearing faults view in spec ("Global/Bearing Settings") + ("Graph Properties/Bearing Faults")
Versión 2.05
28.06.2011
- New mode: stethoscope
Versión 2.03
16.05.2011
- Temporary change settings of sensors in records ("Sensors")
Versión 2.02
22.04.2011
- Graphs with axes and grids
- Graphs alignment ("Global Settings/Align Graphs")
- New cursor types: harmonic, periodic, delta, sideband ("Graph Properties/Cursor")
- Orda trends
- Export of records ("Project/Export")
- Text notices ("Project/Notices")
- ISO 10816 alarms ("Global/ISO Machine Settings")
- Spec peak list ("Graph Properties/Peak List")
- Spec view in RMS, 0P, PP ("Graph Properties/Detect Type")
- Fresp: time signal view, editing of parameters of spec windows ("Graph Properties/Fresp View")
- Cursor movement linear or maxs ("Global Settings/Cursor Type")
- Background colors of graphs ("Global Settings/Background Color")
Versión 2.01
23.02.2011
- First release